网站首页 公司简介 新闻动态 诚聘英才 联系我们  
产品系列
科研级光谱测试系统
科学级成像相机
表面分析测试系统
激光器和光源
FLIM 系统
时间控制系统
耗材材料
光束整形元件
特种镜头
光学平台
光机配件
光镊微操控系统
光学元件检测与装调设备
系统方案设计与服务
光学医学检测
教学演示仪器
栏目列表
新闻动态
公司产品
服务与支持
当前位置: 首页 > 公司产品 > 科研级光谱测试系统 >

SpectraPro HRS 全系列光谱仪

作者: Kevin Peng    发布于: 2019-10-04 21:44    点击:

SpectraPro HRS Spectrographs and Monochromators

image of SpectraPro HRS Spectrographs and Monochromators

New, Versatile, High Resolution Imaging Spectrographs and Scanning Monochromators

For more than 25 years, SpectraPro spectrometers from Princeton Instruments have set new standards for reliable high-performance spectroscopy. Day in and day out, researchers around the world depend on these popular spectrographs and monochromators for a wide variety of scientific and industrial applications.

Building upon the legacy of these iconic research instruments, Princeton Instruments has now created an even more versatile, higher-resolution spectroscopy solution. New SpectraPro HRS imaging spectrographs are absolutely packed with the latest technology and are capable of facilitating just about any spectroscopy application imaginable.

Now available - SpectraPro HRS-750, 750mm focal length

SpectraPro HRS benefits include:

  • Exclusive AccuDrive™ grating drive system yields up to 3X improvement in wavelength accuracy
  • ResXtreme™ spectral deconvolution improves spectral resolution and SNR up to 60%
  • Most precise wavelength and intensity calibration with IntelliCal system
  • High spectral resolution PLUS reduced astigmatism
  • Multiple exit ports provide unrivaled versatility for multi-detector operation
  • Fully supported by 64-bit LightField software

Unrivaled versatility!

The SpectraPro HRS affords researchers truly unrivaled experimental versatility. Dual exit ports, each with a full 30 mm focal plane, permit mounting and operation of two array detectors (which could include any of Princeton Instruments’ CCD, EMCCD, ICCD, sCMOS, or InGaAs detectors) or enable the instrument to operate as both a monochromator and a spectrograph.
 

SpectraPro HRS specifications and datasheets

Model Focal Length Aperture Ratio PMT Resolution* CCD Resolution** Linear
Dispersion*
HRS-300 datasheet pdf 300 mm f/3.9 0.09 nm 0.07 nm or better 2.38 nm/mm
HRS-500 datasheet pdf 500 mm f/6.5 0.05 nm 0.05 nm or better 1.52 nm/mm
HRS-750 datasheet pdf 750 mm f/9.7 0.03 nm 0.03 nm or better 1.03 nm/mm

NOTE:  Please visit the SpectraPro page for 150 focal length models.

* with 1200 g/mm grating @ 435.8 nm and 10 micron slit width and 4 mm slit height | ** with ResXtreme and 1200g/mm grating @ 435.8nm 20 micron pixel, 20 micron slit width

Gratings and Grating Sets for SpetraPro HRS Series

Gratings

 

 

    

 

CLICK THE IMAGE BELOW FOR HRS-300 CONFIGURATIONS

New ResXtreme spectral
deconvolution technology
  • Improves spectral resolution by up to 60%

  • Improves peak intensity of spectral lines by up to 60%

  • Provides up to a 60% improvement in spectral uniformity at all CCD positions

  • Conservation of Energy: Maintains total signal under the peak

  • Improves signal-to-noise performance

  • Saves original spectral information, allowing data to be recalled without ResXtreme

  • Is included with all SpectraPro HRS spectrographs that are purchased with Princeton Instruments LightField software!*

* LightField required for operation of ResXtreme.

 

 

 


 

 

Full-size dual focal planes for multiple array detectors
  • Permits mounting and operation of two cameras
     
  • Choose from Princeton Instruments CCDs and InGaAs cameras for UV – SWIR coverage
     
  • Enables operation as both a monochromator and a spectrograph

AccuDrive™
  • Dramatically improves wavelength accuracy and repeatability
     
  • Outperforms previous scan systems - yields significant improvements in accuracy and reproducibility
     
  • Automatically identifies the turret and gratings installed on startup
     
  • Performs several optical alignment routines to insure accurate initialization
IntelliCal®
IntelliCal wavelength calibration achieves up to 10x greater wavelength calibration accuracy than conventional calibration methods, while IntelliCal intensity calibration removes unwanted instrument responses from spectral data. SpectraPro HRS spectrographs with IntelliCal ensure authentic spectroscopic data that can be published or shared across multiple user facilities.


 

High-efficiency Acton optical coatings
  • Acton #1900 enhanced-aluminum mirrors provide highest reflectivity from 193 nm to mid-IR
     
  • Optional Acton protected silver coatings provide an average > 98% reflectivity and increased throughput over conventional silver coatings
     
  • Optional gold coatings available for NIR
 

 


 
Powerful LightField software
  • Intuitive software package, with cutting-edge user interface
     
  • Provides complete control of entire spectroscopy system and experiment*
     
  • Controls SpectraPro HRS, Princeton Instruments’ cameras, spectral acquisition, data processing and more
 
* Software sold separately

 

 

 

Applications for SpectraPro spectrometers include:

Raman spectroscopy | Fluorescence | Photoluminescence | Plasma emission | Absorption | Transmission | Laser-induced breakdown spectroscopy (LIBS) | Microspectroscopy



Tip-Enhanced Raman Spectroscopy
TERS - Tip-Enhanced Raman spectroscopy

Laser-Induced Breakdown Spectroscopy
LIBS is considered one of the most convenient and efficient analytical techniques for trace elemental analysis in gases, solids, and liquids. LIBS spectra obtained by the Mars Curiosity Rover have confirmed that our sister planet could have harbored life

Absorbance, Reflectance and Transmission
A measure of the amount of light absorbed by a sample as a beam of light passes through it.

Fluorescence, Phosphorescence, and Photoluminescence Spectroscopy
Fluorescence, phosphorescence and photoluminescence occur when a sample is excited by absorbing photons and then emits them with a decay time that is characteristic of the sample environment.

General Raman
The most common application of Raman spectroscopy involves the vibrational energy levels of a molecule. Incident laser light in the UV, visible or NIR, is scattered from molecular vibrational modes.

Plasma Emission Spectroscopy
The different types of plasma emission spectroscopy can be categorized by how the plasma is generated. Spectra of nuclear fusion plasmas are used to ascertain the chemical species present and other properties











|关于我们|联系方式|客户留言|服务与支持|相关知识|友情链接|
Copyright © 2013-2022 FredorScience. 弗锐达科技 版权所有 沪ICP备13044418号-1